GSUG Geothermal Vertical Two Speed Heat Pump with Desuperheater
Features
and Benefits
The geothermal heat pump system consists of:
- a water-source heat pump;
- a closed loop ground heat exchanger made of high density polyethylene pipe (guaranteed
25 years or more by many manufacturers); and
- a low wattage circulating pump(s).
In the heating mode, the closed-loop heat exchanger absorbs heat from the earth
(typically 50 F to 70 F) and transfers the heat to the refrigerant via the
water-to-refrigerant heat exchanger. The compressor concentrates the heat absorbed by the
refrigerant before it flows to a coil in the supply air stream. It also heats the air
moving across the coil, and thus the house itself. An antifreeze solution may be added to
the groundloop heat exchanger to prevent system freeze-up when heat pump leaving water
temperatures drop below the freezing point of water, 32 F.
In the cooling mode, the heat pump extracts heat and moisture from the air and rejects
the heat into the refrigerant. The heat is transferred to the fluid in the ground loop
system via the heat exchanger. The ground then absorbs the heat from the ground loop.
As a benefit of the system, in the cooling mode unwanted heat can be captured by a
desuperheater and used to produce virtually free hot water by reducing the hot water
heater's run time. The desuperheater can also be used to greatly reduce the cost of
producing hot water in the heating mode by reducing the hot water heater's run time.
Trane's high efficiency residential water-source heat pumps offer EERs up to 20.
Moderate earth temperatures translate into the highest comfort levels in cooling from
increased dehumidification and higher supply air temperatures in heating.
Another benefit is that the system requires no defrost cycle and little to no
supplemental heat.
The GSUG unit is located entirely within the home, much like a refrigerator. By
avoiding outside weather extremes, the unit's life span is expanded. Field refrigerant
connections, and an outdoor air conditioning unit are no longer needed.
The unit is compact enough to be installed just about anywhere: placed in an attic,
basement, or tucked away in a closet.
Dependable Design
Cabinet
The cabinet is constructed of heavy gauge galvanized steel. In addition, the cabinet
has a Soft Dove electrostatic powder-paint coating for a longer lasting and
corrosion-resistant finish.
Sound
All units have a thermal/acoustical insulated partition between the blower and
compressor compartments to attenuate any compressor noise.
Fan motors and compressors are internally isolated to reduce vibration. Compressor base
plate and full-length channel stiffeners also help reduce vibration. The GE ICM-2
variable-speed blower motor, with a soft start at 50% capacity, helps reduce start-up
noise and enhance comfort.
Compressor
A high efficiency, 2-speed, reciprocating, Copeland compressor helps assure
quiet, reliable, and efficient operation.
Condensate Pan
Each unit has a removable, cleanable condensate pan to improve indoor air quality. This
condensate pan allows any condensate from the coil to drain freely, discouraging
condensate buildup and microbial growth in the pan.
Filter Rack and Filter
Each unit is equipped with an accessible filter rack, which houses 1-inch standard
sized, disposable, fiberglass filter.
Filter Drier
This unit has a filter drier to dehydrate and clean the refrigerant circuit, adding to
the life of the unit.
Desuperheater and Pump
The factory installed, internal, double-wall vented desuperheater uses heat rejected
from the unit to preheat a home's domestic hot water.
Hot water is provided at virtually no cost to the user during cooling operation, and
very efficiently during heating operation, by reducing the amount of time the hot water
heater runs.
The desuperheater is controlled by two temperature control sensors. One sensor monitors
the temperature of the compressor's discharge line. The desuperheater pump cannot operate
until the compressor line reaches 145 F. The other sensor monitors the water temperature
of the hot water heater. The desuperheaterwill automatically shut off if the water reaches
125 F to prevent scalding and the pump from overheating.
Brazed Plate Heat Exchanger
The stainless steel brazed plate water-to-refrigerant heat exchanger has a low-hydronic
pressure drop and it has a high corrosion resistance because of its stainless steel
construction.
The brazed plate heat exchanger provides a larger amount of surface area for heat
exchange between the water and the refrigerant than traditional tube-in-tube heat
exchanger designed.
Tubing
All low-side tubing in the refrigeration circuit is insulated to prevent condensation
inside the unit.
Expansion Valve
All units are equipped with a balanced port, bi-directional thermal expansion valve.
The valve precisely meters the refrigerant flow through the circuit.
With only a single expansion valve, no check valves are required on the unit.
Safety
The GSUG was designed with safety and maximum protection in mind. High- and
low-pressure cutouts are included to protect the compressor. A freezestat is included to
protect the unit from unusually cold fluid-flow and low fluid-flow conditions. The lockout
relay will turn off the compressor, loop pump, and the desuperheater pump, if a problem is
detected.
Duct Collar
A return-air duct collar is provided with each unit to provide an adequate connection
for duct work, while maintaining access to air filters. With the collar, ductwork can be
easily fastened to the unit, eliminating the need for extra sheet metal work.
In many applications, when the ductwork is insulated, the performance of the unit is
enhanced.
Installation
Blower
Each unit is equipped with an ICM-2 blower motor with soft start.
The ICM-2 blower motor offers increased efficiency, better humidity control, reduced
noise, and higher comfort levels.
Brass Swivel Fittings
Each unit includes 1-inch brass swivel connectors, eliminating the need for a backup
wrench when tightening the water connections. Each brass swivel fitting has a 1-inch
gasket for the connector. The gaskets are shipped in the electrical compartment to prevent
loss.
Return Air Configuration
The GSUG may be ordered with a left- or right-hand return, increasing installation
configuration options.
Field Installed Internal Electric Heat
The GSUG unit is designed for simple field installation of internal backup heat.
Access Panels
The unit has four, removable, access panels (three front, one rear) for access to
internal components. The majority of unit's components may be readily reached through the
three front access panels.
Filters
The GSUG's filters are removable from both sides of the unit, offering added
flexibility for installation and replacing the standard, 1-inch, disposable, fiberglass
filters.
The design of the GSUG filter allows the installer to keep the ductwork in tact when
changing filters.
Service and Maintenance
Control Box
The large control box facilitates any required troubleshooting and service work.
Refrigerant and Service Ports
The unit includes high- and low-side service ports and a water regulating valve
connection, external to cabinet.
| GSUG Physical Data |
| Unit Size |
Width (in) |
Depth (in) |
Height (in) |
Shipping Weight (lbs)
|
Unit Weight (lbs) |
R-22 (lbs) |
| 048 |
26 |
32 |
54 |
373 |
363 |
7.25 |
| 060 |
26 |
32 |
54 |
395 |
385 |
7.50 |
| 072 |
26 |
32 |
54 |
401 |
391 |
7.25 |
As part of its continuous product improvement, The
Trane Company reserves the right to change specifications and design without notice. Read
important energy cost and efficiency information available from your dealer. |